T1 - Use of mini-CT specimens for fracture toughness characterization of low upper-shelf linde 80 weld before and after irradiation1
AU - Sokolov, Mikhail A.
N1 - Publisher Copyright:
Copyright © 2018 ASME.
PY - 2018
Y1 - 2018
N2 - Mini-CT specimens are becoming a highly popular geometry for use in reactor pressure vessel (RPV) community for direct measurement of fracture toughness in the transition region using the Master Curve methodology. In the present study, Mini-CT specimens were machined from previously tested Charpy specimens of the Midland low upper-shelf Linde 80 weld in both, unirradiated and irradiated conditions. The irradiated specimens have been characterized as part of a joint ORNL-EPRI-CRIEPI collaborative program. The Linde 80 weld was selected because it has been extensively characterized in the irradiated condition by conventional specimens, and because of the need to validate application of Mini-CT specimens for low upper-shelf materials - a more likely case for some irradiated materials of older generation RPVs. It is shown that the fracture toughness reference temperatures, To, derived from these Mini-CT specimens are in good agreement with To values previously recorded for this material in the unirradiated and irradiated conditions. However, this study indicates that in real practice it is highly advisable to use a much larger number of specimens than the minimum number prescribed in ASTM E1921.
AB - Mini-CT specimens are becoming a highly popular geometry for use in reactor pressure vessel (RPV) community for direct measurement of fracture toughness in the transition region using the Master Curve methodology. In the present study, Mini-CT specimens were machined from previously tested Charpy specimens of the Midland low upper-shelf Linde 80 weld in both, unirradiated and irradiated conditions. The irradiated specimens have been characterized as part of a joint ORNL-EPRI-CRIEPI collaborative program. The Linde 80 weld was selected because it has been extensively characterized in the irradiated condition by conventional specimens, and because of the need to validate application of Mini-CT specimens for low upper-shelf materials - a more likely case for some irradiated materials of older generation RPVs. It is shown that the fracture toughness reference temperatures, To, derived from these Mini-CT specimens are in good agreement with To values previously recorded for this material in the unirradiated and irradiated conditions. However, this study indicates that in real practice it is highly advisable to use a much larger number of specimens than the minimum number prescribed in ASTM E1921.
UR - http://www.scopus.com/inward/record.url?scp=85056852118&partnerID=8YFLogxK
U2 - 10.1115/PVP201884804
DO - 10.1115/PVP201884804
M3 - Conference contribution
AN - SCOPUS:85056852118
T3 - American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP
BT - Codes and Standards
PB - American Society of Mechanical Engineers (ASME)
T2 - ASME 2018 Pressure Vessels and Piping Conference, PVP 2018
Y2 - 15 July 2018 through 20 July 2018
ER -