Abstract
An approach is developed to study the stability of mixed convection in the poloidal flows of the DCLL blanket. Modified Orr-Sommerfeld equations are derived and then solved using a numerical code based on a pseudo-spectral method. The stability analysis has been performed for the flows in the front blanket ducts, where the forced flow is upwards; showing that in the DCLL blanket conditions, all disturbances associated with the buoyant flows in the front ducts will likely be damped by a strong toroidal magnetic field.
Original language | English |
---|---|
Pages (from-to) | 851-855 |
Number of pages | 5 |
Journal | Fusion Science and Technology |
Volume | 56 |
Issue number | 2 |
DOIs | |
State | Published - Aug 2009 |
Externally published | Yes |