Abstract
We present the optical design of the liquids reflectometer currently under construction at the Spallation Neutron Source. By utilizing a multi-channel bender and a tapered guide, we can eliminate sample-moderator line-of-sight and provide angular dispersion for reflectivity measurements of liquid surfaces. The fast-neutron background of such an instrument is comparable to that present in a direct-view instrument employing a 30-cm thick Inconel t0 chopper.
Original language | English |
---|---|
Pages (from-to) | S1610-S1612 |
Journal | Applied Physics A: Materials Science and Processing |
Volume | 74 |
DOIs | |
State | Published - Dec 2002 |
Externally published | Yes |