The effect of detector resolution for quantitative analysis of neutron stimulated emission computed tomography

Janelle E. Bender, Carey E. Floyd, Brian P. Harrawood, Anuj J. Kapadia, Amy C. Sharma, Jonathan L. Jesneck

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

4 Scopus citations

Abstract

Previous research has shown benign and cancerous tissues to have different chemical make-ups. To measure the elemental concentration of biological samples noninvasively, we used neutron stimulated emission computed tomography (NSECT). When an incident neutron scatters inelastically from an atomic nucleus, it emits characteristic gamma energies, allowing for measurement of the elemental concentration of biological samples. Thus NSECT has the potential to be a method for precancerous tissue detection. In Monte Carlo simulations, we bombarded both a benign and a malignant human breast with 50 million neutrons. The resulting photon spectra were blurred to model the detector resolutions and then analyzed for peak detection. This simulation study analyzed the characteristic spectra using three detectors of different resolutions: a High-Purity Germanium (HPGe) semiconductor, a Bismuth Germanate (BGO) scintillator, and a Sodium Iodide (NaI) scintillator. The effective energy resolutions of these detectors are 0.1%, 7%, and 12%, respectively. The detectability of element peaks in the breast model was greatly reduced when the blur increased from just 0.1% to 7%. These initial experiments are valuable in choosing optimal detectors for peak detection in further NSECT studies and indicate that high-resolution detectors, such as HPGe, are required for using spectral peak analysis for breast cancer prediction.

Original languageEnglish
Title of host publicationMedical Imaging 2006
Subtitle of host publicationPhysics of Medical Imaging
DOIs
StatePublished - 2006
Externally publishedYes
EventMedical Imaging 2006: Physics of Medical Imaging - San Diego, CA, United States
Duration: Feb 12 2006Feb 16 2006

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6142 III
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2006: Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period02/12/0602/16/06