The Continuous Electron Beam Accelerator Facility at 12 GeV

P. A. Adderley, S. Ahmed, T. Allison, R. Bachimanchi, K. Baggett, M. Bastaninejad, B. Bevins, M. Bevins, M. Bickley, R. M. Bodenstein, S. A. Bogacz, M. Bruker, A. Burrill, L. Cardman, J. Creel, Y. C. Chao, G. Cheng, G. Ciovati, S. Chattopadhyay, J. ClarkW. A. Clemens, G. Croke, E. Daly, G. K. Davis, J. Delayen, S. U. De Silva, M. Diaz, R. Dickson, L. Doolittle, D. Douglas, M. Drury, E. Feldl, J. Fischer, A. Freyberger, V. Ganni, R. L. Geng, C. Ginsburg, J. Gomez, J. Grames, J. Gubeli, J. Guo, F. Hannon, J. Hansknecht, L. Harwood, J. Henry, C. Hernandez-Garcia, T. Hiatt, D. Higinbotham, S. Higgins, A. S. Hofler, J. Hogan, C. Hovater, A. Hutton, C. Jones, K. Jordan, M. Joyce, R. Kazimi, M. Keesee, M. J. Kelley, C. Keppel, A. Kimber, L. King, P. Kjeldsen, P. Kneisel, J. Kowal, G. A. Krafft, G. Lahti, T. Larrieu, R. Lauze, C. Leemann, R. Legg, R. Li, F. Lin, D. Machie, J. Mammosser, K. Macha, K. Mahoney, F. Marhauser, B. Mastracci, J. Matalevich, J. McCarter, M. McCaughan, L. Merminga, R. Michaud, V. Morozov, C. Mounts, J. Musson, R. Nelson, W. Oren, R. B. Overton, G. Palacios-Serrano, H. K. Park, L. Phillips, S. Philip, F. Pilat, T. Plawski, M. Poelker, P. Powers, T. Powers, J. Preble, T. Reilly, R. Rimmer, C. Reece, H. Robertson, Y. Roblin, C. Rode, T. Satogata, D. J. Seidman, A. Seryi, A. Shabalina, I. Shin, C. Slominski, R. Slominski, M. Spata, D. Spell, J. Spradlin, M. Stirbet, M. L. Stutzman, S. Suhring, K. Surles-Law, R. Suleiman, C. Tennant, H. Tian, D. Turner, M. Tiefenback, O. Trofimova, A. M. Valente, H. Wang, Y. Wang, K. White, C. Whitlatch, T. Whitlatch, M. Wiseman, M. J. Wissman, G. Wu, S. Yang, B. Yunn, S. Zhang, Y. Zhang

Research output: Contribution to journalReview articlepeer-review

2 Scopus citations

Abstract

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV/m. After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix.

Original languageEnglish
Article number084802
JournalPhysical Review Accelerators and Beams
Volume27
Issue number8
DOIs
StatePublished - Aug 2024

Funding

This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under Contract No. DE-AC05-06OR23177. As is typical for review papers of this type, authors, who may have worked at one time at Jefferson Lab on some aspect of the 12 GeV project may no longer be working there. In the affiliation list for this paper, the present or final institutional association of the author is listed.

Fingerprint

Dive into the research topics of 'The Continuous Electron Beam Accelerator Facility at 12 GeV'. Together they form a unique fingerprint.

Cite this