The CG-1D Neutron Imaging Beamline at the Oak Ridge National Laboratory High Flux Isotope Reactor

Lou Santodonato, Hassina Bilheux, Barton Bailey, Jean Bilheux, Phong Nguyen, Anton Tremsin, Doug Selby, Lakeisha Walker

Research output: Contribution to journalConference articlepeer-review

58 Scopus citations

Abstract

The Oak Ridge National Laboratory Neutron Sciences Directorate has installed a neutron imaging beamline at the High Flux Isotope Reactor (HFIR) cold guide hall. CG-1D is one of the three instruments that make up the CG1 instrument suite. The beamline optics and detector have recently been upgraded to meet the needs of the neutron imaging community (better "smoothing" of guide system artifacts, higher flux or spatial resolution). These upgrades comprise a new diffuser/aperture system, two new detectors, a He-filled flight tube and silicon (Si) windows. Shielding inside the flight tube, beam scrapers and a beam stop ensure that biological dose is less than 50 μSv/hr outside of the radiation boundary. A set of diffusers and apertures (pinhole geometry) has been installed at the exit of the guide system to allow motorized L/D variation. Samples sit on a translation/rotation stage for alignment and tomography purposes. Detectors for the CG-1D beamline are (1) an ANDOR DW936 charge coupled device (CCD) camera with a field of view of approximately 7 cm x 7 cm and ∼ 80 microns spatial resolution and 1 frame per second time resolution, (2) a new Micro-Channel Plate (MCP) detector with a 2.8 cm x 2.8 cm field of view and 55 microns spatial resolution, and 5 μs timing capability. 6LiF/ZnS scintillators of thickness varying from 50 to 200 microns are being used at this facility. An overview of the beamline upgrade and preliminary data is presented here.

Original languageEnglish
Pages (from-to)104-108
Number of pages5
JournalPhysics Procedia
Volume69
DOIs
StatePublished - 2015
EventProceedings of the 10th World Conference on Neutron Radiography, WCNR-10 2014 - Grindelwald, Switzerland
Duration: Oct 5 2014Oct 10 2014

Funding

Notice: This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes.

FundersFunder number
Office of Basic Energy Sciences
Scientific User Facilities Division
US Department of Energy
Oak Ridge National Laboratory
Laboratory Directed Research and Development

    Keywords

    • CCD
    • MCP
    • aperture
    • beamline optics
    • cold neutrons
    • diffuser
    • neutron radiography

    Fingerprint

    Dive into the research topics of 'The CG-1D Neutron Imaging Beamline at the Oak Ridge National Laboratory High Flux Isotope Reactor'. Together they form a unique fingerprint.

    Cite this