Testing single phase IGBT H-bridge switch plates for the high voltage converter modulator at the Spallation Neutron Source

Vladimir V. Peplov, David E. Anderson, Dennis J. Solley

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

Three IGBT H-bridge switching networks are used in each High Voltage Converter Modulator (HVCM) system at the Spallation Neutron Source (SNS) to generate drive currents to three boost transformer primaries switching between positive and negative bus voltages at 20 kHz. Every switch plate assembly is tested before installing it into an operational HVCM. A Single Phase Test Stand has been built for this purpose, and it is used for adjustment, measurement and testing of different configurations of switch plates. This paper will present a description of the Test Stand configuration and discuss the results of testing switch plates with two different types of IGBT gate drivers currently in use on the HVCM systems. Comparison of timing characteristics of the original and new drivers and the resulting performance reinforces the necessity to replace the original H-bridge network drivers with the upgraded units.

Original languageEnglish
Title of host publicationProceedings of the 2014 IEEE International Power Modulator and High Voltage Conference, IPMHVC 2014
EditorsAllen L. Garner
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages676-679
Number of pages4
ISBN (Electronic)9781467373234
DOIs
StatePublished - 2014
EventIEEE International Power Modulator and High Voltage Conference, IPMHVC 2014 - Santa Fe, United States
Duration: Jun 1 2014Jun 5 2014

Publication series

NameProceedings of the 2014 IEEE International Power Modulator and High Voltage Conference, IPMHVC 2014

Conference

ConferenceIEEE International Power Modulator and High Voltage Conference, IPMHVC 2014
Country/TerritoryUnited States
CitySanta Fe
Period06/1/1406/5/14

Fingerprint

Dive into the research topics of 'Testing single phase IGBT H-bridge switch plates for the high voltage converter modulator at the Spallation Neutron Source'. Together they form a unique fingerprint.

Cite this