Small specimen data from a high temperature HFIR irradiation experiment

Tim Burchell, Joel McDuffee, Ken Thorns

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

4 Scopus citations

Abstract

The HTV capsule is a High Flux Isotope Reactor (HFIR) target-rod capsule designed to operate at very high temperatures. The graphite containing section of the capsule (in core) is approximately 18 in. (457.2 mm) long and is separated into eight temperature zones. The specimen diameters within each zone are set to achieve the desired gas gap and hence design temperature (900, 1200, or 1500°C). The capsule has five zones containing 0.400 in. 00.16 mm) diameter specimens, two zones containing 0.350 in. (8.89 mm) diameter specimens and one zone containing 0.300 in. (7.62 mm) diameter specimens. The zones have been distributed within the experiment to optimize the gamma heating from the HFIR core as well as minimize the axial heat flow in the capsule. Consequently, there are two 900°C zones, three 1200°C zones, and three 1500°C zones within the HTV capsule. Each zone contains nine specimens 0.210 ±0.002 in. (5.334 mm) in length. The capsule will be irradiated to a peak dose of 3.17 displacements per atom. The HTV specimens include samples of the following graphite grades: SGL Carbon's NBG-17 and NBG-18, GrafTech's PCEA, Toyo Tanso's IG-110, Mersen's 2114, and the reference grade H-451 (SGL Carbon). As part of the pre-irradiation program, the specimens were characterized using ASTM Standards C559 for bulk density, and ASTM C769 for approximate Young's modulus from the sonic velocity. The probe frequency used for the determination of time of flight of the ultrasonic signal was 2.25 MHz. Marked volume (specimen diameter) effects were noted for both bulk density (increased with increasing specimen volume or diameter) and dynamic Young's modulus (decreased with increasing specimen volume or diameter). These trends are extended by adding the property versus diameter data for unirradiated AGC-1 creep specimens (nominally 12.5mm-diameter by 25.4mm-length). The relatively large reduction in dynamic Young's modulus was surprising given the trend for increasing density with increasing volume. The graphite-filler particle size was noted to be influential in the volume dependency data, with finer grained graphites showing the least specimen volume/diameter effect. Here the volume dependency trends are discussed in terms of the graphite's filler-particle size and texture.

Original languageEnglish
Title of host publicationGraphite Testing for Nuclear Applications
Subtitle of host publicationThe Significance of Test Specimen Volume and Geometry and the Statistical Significance of Test Specimen Population
EditorsMark C. Carroll, Athanasia Tzelepi
PublisherASTM International
Pages172-185
Number of pages14
ISBN (Electronic)9780803176010
DOIs
StatePublished - 2014
EventSymposium on Graphite Testing for Nuclear Applications: The Significance of Test Specimen Volume and Geometry and the Statistical Significance of Test Specimen Population - Seattle, United States
Duration: Sep 19 2013Sep 20 2013

Publication series

NameASTM Special Technical Publication
VolumeSTP 1578
ISSN (Print)0066-0558

Conference

ConferenceSymposium on Graphite Testing for Nuclear Applications: The Significance of Test Specimen Volume and Geometry and the Statistical Significance of Test Specimen Population
Country/TerritoryUnited States
CitySeattle
Period09/19/1309/20/13

Funding

FundersFunder number
U.S. Department of Energy

    Keywords

    • Carbon
    • Graphite
    • Nuclear
    • Physical properties

    Fingerprint

    Dive into the research topics of 'Small specimen data from a high temperature HFIR irradiation experiment'. Together they form a unique fingerprint.

    Cite this