Abstract
The thermal performance of fenestration in commercial buildings can have a significant effect on building loads - yet there is little information on the performance of these products. With this in mind, ASHRAE TC 4.5, Fenestration, commissioned a research project involving test and simulation of commercial fenestration systems. The objectives of ASHRAE Research Project 877 were: to evaluate the thermal performance (U-factors) of commonly used commercial glazed roof and wall assemblies; to obtain a better fundamental understanding of the heat transfer processes that occur in these specialty fenestration products; to develop correlations for natural-convection heat transfer in complex glazing cavities; to develop a methodology for evaluating complex fenestration products, suitable for inclusion in ASHRAE Standard 142P (ASHRAE 1996); and to generate U-factors for common commercial fenestration products, suitable for inclusion in the ASHRAE Handbook - Fundamentals. This paper describes testing and simulation of pyramid and barrel vault skylight specimens and provides guidelines for modeling these systems based on the validated results.
Original language | English |
---|---|
Pages (from-to) | 832-844 |
Number of pages | 13 |
Journal | ASHRAE Transactions |
Volume | 104 |
Issue number | Pt 1B |
State | Published - 1998 |
Externally published | Yes |
Event | Proceedings of the 1998 ASHRAE Winter Meeting. Part 1 (of 2) - San Francisco, CA, USA Duration: Jan 18 1998 → Jan 21 1998 |