Abstract
A stochastic simulation is developed for predicting dispersed phase holdup and drop size distribution profiles in column contactors. The framework required to incorporate mass transfer processes is also presented. A stagewise flow model for the continuous phase and the interphase mass transport balances is included. Simulated results are compared to experimental measurements for toluene/water, with good agreement. (P.M.T.)
| Original language | English |
|---|---|
| Title of host publication | Unknown Host Publication Title |
| Publisher | London, U.K.; Elsevier |
| ISBN (Print) | 044488677X, 9780444886774 |
| State | Published - 1992 |