Abstract

Experimental facilities at the Oak Ridge National Laboratory's High Flux Isotope Reactor are being upgraded through the redesign of beam tubes supplying neutrons to those facilities. In support of the shield design for one of the beam lines HB-2, calculations were performed to determine dose rates outside the shielding as well as background radiation levels at various locations around the instrumentation. Low-power (10 % power) as well as full-power measurements were made at key locations, and calculated results were compared with corresponding measured results. This paper describes the calculations and compares the measured and calculated results. Most of the measured results, when normalized to the full-operating-power level, compared favorably with the calculated results. One differed by a factor of 2.5, and another differed by a factor of 6. Based on this agreement, one can infer that reasonable calculations for some three-dimensional shield designs can be performed using two-dimensional methods and two-dimensional approximations to the three-dimensional geometry. The results confirmed the adequacy of the design.

Original languageEnglish
JournalJournal of ASTM International
Volume3
Issue number6
DOIs
StatePublished - 2006

Keywords

  • Beam line
  • Discrete ordinales
  • Dose measurements
  • Dose rates
  • HFIR
  • Monte Carlo
  • Shielding calculations

Fingerprint

Dive into the research topics of 'Shielding calculations for the upgrade of the HFIR HB 2 beam line'. Together they form a unique fingerprint.

Cite this