Setting up and time-resolution measurement of a radio-frequency-based streak camera

A. V. Aleksandrov, N. S. Dikansky, V. Guidi, G. V. Lamanna, P. V. Logatchov, S. V. Shiyankov, L. Tecchio

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

We have experimented with a radio-frequency-based streak camera. The basic idea behind the method consists of magnetic deflection of the electron beam imparted by a radio-frequency cavity. All the components of the camera were tested and the time resolution was measured to lie within the sub-ps domain. Further advantages of the method are simplification of triggering, weaker dependence on space-charge effect within the electron beam, high modularity, and ease of implementation.

Original languageEnglish
Pages (from-to)2622-2626
Number of pages5
JournalReview of Scientific Instruments
Volume70
Issue number6
DOIs
StatePublished - Jun 1999
Externally publishedYes

Fingerprint

Dive into the research topics of 'Setting up and time-resolution measurement of a radio-frequency-based streak camera'. Together they form a unique fingerprint.

Cite this