R.F. input coupler system for the CEBAF energy upgrade cryomodule

J. R. Delayen, L. R. Doolittle, T. Hiatt, J. Hogan, J. Mammosser, L. Phillips, J. Preble, W. J. Schneider, G. Wu

Research output: Contribution to conferencePaperpeer-review

8 Scopus citations

Abstract

Long term plans for CEBAF at Jefferson Lab call for achieving 12 GeV in the middle of the next decade and 24 GeV after 2010. Thus an upgraded cryomodule to more than double the present voltage is under development. A new waveguide coupler system has been designed and prototypes are currently being developed. This coupler, unlike the original, has a nominal Qext of 2.1×107, reduced sensitivity of Qext to mechanical deformation, reduced field asymmetry within the beam envelope, freedom from window arcing with a single window at 300 K, and is capable of transmitting 6 kW CW both traveling wave and in full reflection.

Original languageEnglish
Pages1462-1464
Number of pages3
StatePublished - 1999
Externally publishedYes
EventThe 18th Biennial Particle Accelerator Conference - New York, NY, USA
Duration: Mar 27 1999Apr 2 1999

Conference

ConferenceThe 18th Biennial Particle Accelerator Conference
CityNew York, NY, USA
Period03/27/9904/2/99

Fingerprint

Dive into the research topics of 'R.F. input coupler system for the CEBAF energy upgrade cryomodule'. Together they form a unique fingerprint.

Cite this