Resonance Region Covariance Analysis Method and New Covariance Data for 232Th, 233U, 235U, 238U, and 239Pu

L. C. Leal, G. Arbanas, D. Wiarda, H. Derrien

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

Resonance-parameter covariance matrix (RPCM) evaluations in the resolved resonance region were done for 232Th, 233U, 235U, 238U, and 239Pu using the computer code SAMMY. The retroactive approach of the code SAMMY was used to generate the RPCMs for 233U and 235U. RPCMs for 232Th, 238U and 239Pu were generated together with the resonance parameter evaluations. The RPCMs were then converted in the ENDF format using the File32 representation. Alternatively, for computer storage reasons, the File32 was converted in the File33 cross section covariance matrix (CSCM). Both representations were processed using the computer code PUFF-IV. This paper describes the procedures used to generate the RPCM with SAMMY.

Original languageEnglish
Pages (from-to)2868-2873
Number of pages6
JournalNuclear Data Sheets
Volume109
Issue number12
DOIs
StatePublished - Dec 2008

Funding

This work was sponsored by the U.S. Department of Energy Nuclear Criticality Safety Program (NCSP), under contract DE-AC05-00OR22725 with UT-Battelle, LLC.

FundersFunder number
U.S. Department of Energy Nuclear Criticality Safety ProgramDE-AC05-00OR22725 with UT-Battelle

    Fingerprint

    Dive into the research topics of 'Resonance Region Covariance Analysis Method and New Covariance Data for 232Th, 233U, 235U, 238U, and 239Pu'. Together they form a unique fingerprint.

    Cite this