Radiation measurements vs. Predictions for SNS linac commissioning

I. Popova, D. Gregory, F. Gallmeier, P. Gonzalez

Research output: Contribution to conferencePaperpeer-review

1 Scopus citations

Abstract

To support Spallation Neutron Source (SNS) [1] accelerator commissioning stages, detailed predictions for radiation fields induced inside and outside of the accelerator tunnel were performed using the Monte Carlo code MCNPX. On the basis of neutronics analyses, proper shielding was developed and installed in key locations to reduce dose rates in occupied areas. Absorbed dose and dose equivalent rates were monitored by radiation measurement devices both inside and outside of the tunnel areas. The measured radiation fields were analyzed and compared to radiation transport simulations.

Original languageEnglish
Pages977-979
Number of pages3
StatePublished - 2006
Event10th European Particle Accelerator Conference, EPAC 2006 - Edinburgh, United Kingdom
Duration: Jun 26 2006Jun 30 2006

Conference

Conference10th European Particle Accelerator Conference, EPAC 2006
Country/TerritoryUnited Kingdom
CityEdinburgh
Period06/26/0606/30/06

Fingerprint

Dive into the research topics of 'Radiation measurements vs. Predictions for SNS linac commissioning'. Together they form a unique fingerprint.

Cite this