Pulse duration measurements of grazing-incidence-pumped high repetition rate Ni-like Ag and Cd transient soft x-ray lasers

  • M. A. Larotonda
  • , Y. Wang
  • , M. Berrill
  • , B. M. Luther
  • , J. J. Rocca
  • , Mahendra Man Shakya
  • , S. Gilbertson
  • , Zenghu Chang

Research output: Contribution to journalArticlepeer-review

26 Scopus citations

Abstract

We have measured the pulse duration of gain-saturated 13.9 nm Ni-like Ag and 13.2 nm Ni-like Cd transient collisional lasers excited by grazing-incidence-pumping for several pumping conditions. High-resolution streak-camera measurements yielded FWHM pulse durations close to 5 ps for both lasers under optimum pumping conditions. The very high brightness and short pulse duration of these new high repetition tabletop soft x-ray lasers make them an attractive source for dynamic applications.

Original languageEnglish
Pages (from-to)3043-3045
Number of pages3
JournalOptics Letters
Volume31
Issue number20
DOIs
StatePublished - Oct 15 2006
Externally publishedYes

Fingerprint

Dive into the research topics of 'Pulse duration measurements of grazing-incidence-pumped high repetition rate Ni-like Ag and Cd transient soft x-ray lasers'. Together they form a unique fingerprint.

Cite this