Abstract
This paper describes a technique to determine the core loss data, at high frequencies, using the loss data provided by the lamination manufacturer. Steinmetz equation is used in this proposed method to determine core loss at high frequency. This Steinmetz equation consists of static hysteresis and eddy current loss. The presented technique considers the coefficients of Steinmetz equation as variable with frequency and peak magnetic flux density. The high frequency core loss data, predicted using this model is compared with the catalogue data given by manufacturer and very good accuracy has been obtained for a wide range of frequency.
Original language | English |
---|---|
Pages (from-to) | 248-256 |
Number of pages | 9 |
Journal | Journal of Magnetism and Magnetic Materials |
Volume | 410 |
DOIs | |
State | Published - Jul 15 2016 |
Externally published | Yes |
Keywords
- Curve fitting
- Electrical machines
- Magnetic cores
- Magnetic losses