@inproceedings{89978e79d7e540a3a79a3c374ad22e8e,
title = "P3-3: Measurement of loss in high power 170 GHz gyrotron transmission lines",
abstract = "Over-moded corrugated cylindrical waveguides are used for high power gyrotron radiation transmission applications, such as ITER, because of their low loss characteristics at millimeter wavelengths. Measurements on such over-moded systems are fraught with inaccuracies due to higher order modes. We report a new technique to accurately measure the inherent loss of an over-moded device in the desired operation mode. This technique is demonstrated successfully on low-power measurements at 170GHz in 63.5 mm diameter corrugated ITER transmission lines. We find the miter bend loss to be 0.022 ±0.008 dB (0.5 ±0.2 \%), in good agreement with theory.",
keywords = "Gyrotrons, Millimeter wave measurement, Over-moded, Transmission lines, Waveguide bends",
author = "Kowalski, \{Elizabeth J.\} and Nanni, \{Emilio A.\} and Shapiro, \{Michael A.\} and Sirigiri, \{Jagadishwar R.\} and Temkin, \{Richard J.\} and Bigelow, \{Timothy S.\} and Rasmussen, \{David A.\}",
year = "2010",
doi = "10.1109/IVELEC.2010.5503412",
language = "English",
isbn = "9781424470976",
series = "2010 IEEE International Vacuum Electronics Conference, IVEC 2010",
pages = "335--336",
booktitle = "2010 IEEE International Vacuum Electronics Conference, IVEC 2010",
note = "2010 IEEE International Vacuum Electronics Conference, IVEC 2010 ; Conference date: 18-05-2010 Through 20-05-2010",
}