Operation of TEXTOR-94 with tungsten poloidal main limiters

A. Pospieszczyk, T. Tanabe, V. Philipps, G. Sergienko, T. Ohgo, K. Kondo, M. Wada, M. Rubel, W. Biel, A. Huber, A. Kirschner, J. Rapp, N. Noda

Research output: Contribution to journalArticlepeer-review

45 Scopus citations

Abstract

In TEXTOR-94, experiments have been performed with the upper and lower poloidal limiter blocks made of vapour sprayed (VSP) tungsten (about 0.5 mm) deposited on graphite with a rhenium interlayer. A series of discharge conditions have been performed (density scan, scan of the auxiliary heating power, radius scan). There has been found no restriction for operation at any density with auxiliary heating. For Ohmic conditions the same density with testlimiters could be reached. Under siliconized conditions no severe accumulation of tungsten in the plasma centre could be detected. The blocks could in general stand surface temperatures below 1700 K. Most of them survived also temperatures above 3000 K without exfoliation. However, some blocks showed severe damage by melting or exfoliation probably due to insufficient contact of the tungsten layer with the graphite.

Original languageEnglish
Pages (from-to)947-952
Number of pages6
JournalJournal of Nuclear Materials
Volume290-293
DOIs
StatePublished - Mar 2001
Externally publishedYes

Fingerprint

Dive into the research topics of 'Operation of TEXTOR-94 with tungsten poloidal main limiters'. Together they form a unique fingerprint.

Cite this