Non-invasive estimation of potassium (39K) in Bovine Liver using Neutron Stimulated Emission Computed Tomography (NSECT)

Anuj J. Kapadia, Amy C. Sharma, Georgia D. Tourassi, Janelle E. Bender, Alexander S. Crowell, Matthew R. Kiser, Calvin R. Howell, Carey E. Floyd

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

5 Scopus citations

Abstract

Neutron stimulated emission computed tomography (NSECT) is being developed as a non-invasive technique to measure element concentration in in-vivo tissue at molecular levels. We have developed a system that performs this task using an incident neutron beam that scatters inelastically with an atomic nucleus causing it to emit a characteristic gamma photon. An energy-sensitive gamma detector is used to detect this energy and identify the target atom. Here we describe an experiment to determine the concentration of natural potassium (39K) in bovine liver without the need for a biopsy. A 5 MeV neutron beam was used to scan a known quantity of bovine liver to obtain a gamma spectrum showing element concentration in the liver. An aqueous KCl solution calibration sample was then scanned to establish a ratio of potassium concentration to gamma counts for the experimental setup. Counts from gamma peaks corresponding to excited states in 39K were summed and compared with counts from the known calibration sample, to give the concentration of 39K in the liver. A high purity germanium (HPGe) clover detector was used to measure the emitted gamma energy. The results were validated through neutron activation analysis (NAA) of the liver sample. The concentration of 39K reported by NSECT was found to be within 13% of the NAA result, clearly demonstrating the ability of NSECT for non-invasive quantification of element concentration in tissue.

Original languageEnglish
Title of host publication2006 IEEE Nuclear Science Symposium - Conference Record
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages2076-2078
Number of pages3
ISBN (Print)1424405610, 9781424405619
DOIs
StatePublished - 2006
Externally publishedYes
Event2006 IEEE Nuclear Science Symposium, Medical Imaging Conference and 15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors, Special Focus Workshops, NSS/MIC/RTSD - San Diego, CA, United States
Duration: Oct 29 2006Nov 4 2006

Publication series

NameIEEE Nuclear Science Symposium Conference Record
Volume4
ISSN (Print)1095-7863

Conference

Conference2006 IEEE Nuclear Science Symposium, Medical Imaging Conference and 15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors, Special Focus Workshops, NSS/MIC/RTSD
Country/TerritoryUnited States
CitySan Diego, CA
Period10/29/0611/4/06

Fingerprint

Dive into the research topics of 'Non-invasive estimation of potassium (39K) in Bovine Liver using Neutron Stimulated Emission Computed Tomography (NSECT)'. Together they form a unique fingerprint.

Cite this