Abstract
Using modified vertical Bridgman (MVB) technique, Yinnel has been successfully growing 3-inch-diameter CZT ingots with single crystal volume up to 300cm3 per ingot Using the "best" growth condition, Yinnel can reproducibly grow the CZT with high μτ(e) and μτ(h) products. Baltic Scientific Instruments (B.S.I.) has made six large-size (15×15×10mm3) coplanar detectors, which showed the excellent spectrum resolution (<2%), the best resolution is 1.58%, and Brookhaven National Laboratory (BNL) has made the planar Frisch Grid detector (5×6×11mm3) with the 1.2% resolution (at 5°C) both detectors measured with Cs137 source at 662keV.
Original language | English |
---|---|
Article number | JRM1-2 |
Pages (from-to) | 2320-2323 |
Number of pages | 4 |
Journal | IEEE Nuclear Science Symposium Conference Record |
Volume | 4 |
State | Published - 2004 |
Externally published | Yes |
Event | 2004 Nuclear Science Symposium, Medical Imaging Conference, Symposium on Nuclear Power Systems and the 14th International Workshop on Room Temperature Semiconductor X- and Gamma- Ray Detectors - Rome, Italy Duration: Oct 16 2004 → Oct 22 2004 |