Abstract

This report details the specifics of applying the Position-Averaged Method to the target wedges and staves. The methodology used to calculate the decay gamma sources for a single target wedge to the calculation of the Second Target Station (STS) target assembly activation and the resulting decay gamma source terms are detailed in this report. The methodology has been applied to the entire STS target assembly including all of the target wedges, staves, shaft, and drive. The target staves and shaft have been vertically segmented to ensure the decay gamma source gradient is sufficiently captured. MCNP® Code Version 6.2.0 with the RNUCS patch coupled with CINDER2008 from the AARE V1.0 package are the main tools used to calculate the decay gamma source terms.
Original languageEnglish
Place of PublicationUnited States
DOIs
StatePublished - Apr 2024

Keywords

  • 73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Fingerprint