Abstract

Interface dimensions of the full production run of 360 CEBAF cavities manufactured by Siemens are summarized. Analysis indicated that length tolerances of ±2 mm and fundamental power coupler location tolerances of ±0.15 mm are achievable on future procurements. Vacuum leaks were a concern early in production but have now been overcome: 2 K helium leak rates integrated over 22 vacuum seals have been measured on 84 cavity pairs and a roughly normal distribution of the log10 (leak rate) is seen, centered about a rate of 10-10.2 torr-1/s.