Abstract
KSTAR (Korea Superconducting Tokamak Advanced Research) CS(Central Solenoid) model coil made with CIC(Cable in Conduit) superconductor had been developed in Department of Nuclear Engineering, Seoul National University. In superconducting magnets, there are mechanical stresses by Lorentz force and thermal stresses by the difference of thermal contraction between conduit and insulator. In this study, the computational analysis with ANSYS, a common FEA(Finite Element Analysis) code, and experimental measurements of KSTAR CS model coil with resistance foil type strain gages have been done According to the results of computational analysis, KSTAR CS model coil satisfies safety design limitations. Experimental results obtained from the test of KSTAR CS model coil were compared with those of computational analysis.
Original language | English |
---|---|
Pages (from-to) | 228-231 |
Number of pages | 4 |
Journal | IEEE Transactions on Applied Superconductivity |
Volume | 9 |
Issue number | 2 PART 1 |
DOIs | |
State | Published - 1999 |
Externally published | Yes |