Key reactor system components in integral pressurized water reactors (iPWRs)

Research output: Chapter in Book/Report/Conference proceedingChapterpeer-review

5 Scopus citations

Abstract

The near-term SMRs are implementing a variety of integral pressurized water reactor (iPWR) designs. However, the principle iPWR reactor coolant system components are typically identical in function to similar components in larger LWRs, but the size and, more significantly, the location of many of these components has been modified. This chapter discusses individual components associated with the integral reactor coolant system and external systems and components connected to the reactor coolant system. Key differences from current PWR designs along with PWR design commonalities are highlighted throughout the chapter.

Original languageEnglish
Title of host publicationHandbook of Small Modular Nuclear Reactors
Subtitle of host publicationSecond Edition
PublisherElsevier
Pages95-115
Number of pages21
ISBN (Electronic)9780128239162
DOIs
StatePublished - Jan 1 2020

Keywords

  • CRDM
  • Component
  • Control rod
  • ECCS
  • LOCA
  • Pressure vessel
  • Pressurizer
  • Primary system
  • RCS piping
  • Steam generator

Fingerprint

Dive into the research topics of 'Key reactor system components in integral pressurized water reactors (iPWRs)'. Together they form a unique fingerprint.