The ITER International Organization has developed a number of reference Monte Carlo N-Particle (MCNP) models including the tokamak machine C-model, the Tokamak Complex model, and the neutral beam injection (NBI) systems model. The Tokamak Complex model primarily describes building structures beyond the bioshield. Representation of the tokamak and its systems are not included in this model. The Oak Ridge National Laboratory Radiation Transport Group has conducted two ITER neutronic analysis model integrations: (1) integration of the tokamak C-model with the Tokamak Complex model for shutdown dose rate characterization in Port Cell 16 at level B1, and (2) integration of the NBI model with the Tokamak Complex model for estimating the spatial distribution of biological dose rate at levels L1, L2, and L3 of the Tokamak Complex. The integrated models were further extended to include models of system components that are essential to the neutronic analyses. This paper presents the approach and computer tools used to integrate existing reference models, describes the additional design details implemented in the integrated models, and provides representative neutronic calculations based on the extended models.
Original language | English |
---|---|
Pages (from-to) | 277-287 |
Number of pages | 11 |
Journal | Fusion Science and Technology |
Volume | 74 |
Issue number | 4 |
DOIs | |
State | Published - Nov 17 2018 |
Keywords
- C-model
- ITER
- Tokamak Complex model
- model integration
- neutronic analyses