Abstract
Improving efficiency of plasma generation in RF Hsurface plasma source (SPS) with saddle (SA) RF antenna is considered. Several versions of new plasma generators with different antennas and magnetic field configurations were tested in the SNS small Test Stand. The efficiency of positive ion plasma generation has been improved ∼4x times up to 0.18 A/cm2 per 1 kW of RF power 13.56 MHz. A first prototype SA SPS with AlN chamber was installed in the SNS Test that achieved current of H- ions up to 67 mA with an apparent efficiency of up to 1.6 mA/kW at RF frequency 2 MHz. A new version of the RF assisted triggering plasma source (TPS) has been designed, fabricated and tested. A Saddle antenna SPS with water cooling is being fabricated for high duty factor have been tested.
Original language | English |
---|---|
Pages | 439-441 |
Number of pages | 3 |
State | Published - 2012 |
Event | 23rd Russian Particle Accelerator Conference, RuPAC 2012 - Saint-Petersburg, Russian Federation Duration: Sep 24 2012 → Sep 28 2012 |
Conference
Conference | 23rd Russian Particle Accelerator Conference, RuPAC 2012 |
---|---|
Country/Territory | Russian Federation |
City | Saint-Petersburg |