TY - JOUR
T1 - Implementation of coherence imaging spectroscopy for ion flow measurements in the Compact Toroidal Hybrid experiment
AU - Allen, N.
AU - Ennis, D.
AU - Allen, S.
AU - Samuell, C.
AU - Kriete, D.
AU - Johnson, C.
AU - Hartwell, G.
AU - Maurer, D.
N1 - Publisher Copyright:
© 2023 The Author(s)
PY - 2023/6/1
Y1 - 2023/6/1
N2 - A new coherence imaging spectroscopy (CIS) system has been characterized and validated for measurements of impurity ion velocity in the Compact Toroidal Hybrid (CTH) experiment. CIS is an interferometric technique providing very high spatial resolution of line-integrated ion flows; however, these measurements are highly sensitive to environmental factors such as temperature fluctuations. A compact interferometer design housed in a thermally regulated environment yields CIS measurement variations due to thermal fluctuations of 0.25 km/s. CIS measurements of He+ flows in the outer regions of CTH are benchmarked using two optical grating spectrometers. The deviation between the measurements is typically less than 2 km/s for multiple lines of sight which is well within the uncertainties of the diagnostics. Additional experiments demonstrate a moderate robustness of ion flows in the outer region of CTH to changing the vacuum transform, direction of the magnetic field, and plasma current. In contrast, regions of complete flow reversal are observed when a bias probe is inserted into the plasma edge.
AB - A new coherence imaging spectroscopy (CIS) system has been characterized and validated for measurements of impurity ion velocity in the Compact Toroidal Hybrid (CTH) experiment. CIS is an interferometric technique providing very high spatial resolution of line-integrated ion flows; however, these measurements are highly sensitive to environmental factors such as temperature fluctuations. A compact interferometer design housed in a thermally regulated environment yields CIS measurement variations due to thermal fluctuations of 0.25 km/s. CIS measurements of He+ flows in the outer regions of CTH are benchmarked using two optical grating spectrometers. The deviation between the measurements is typically less than 2 km/s for multiple lines of sight which is well within the uncertainties of the diagnostics. Additional experiments demonstrate a moderate robustness of ion flows in the outer region of CTH to changing the vacuum transform, direction of the magnetic field, and plasma current. In contrast, regions of complete flow reversal are observed when a bias probe is inserted into the plasma edge.
KW - Plasma diagnostics - interferometry, spectroscopy and imaging
KW - Plasma diagnostics - probes
UR - http://www.scopus.com/inward/record.url?scp=85163827390&partnerID=8YFLogxK
U2 - 10.1088/1748-0221/18/06/P06030
DO - 10.1088/1748-0221/18/06/P06030
M3 - Article
AN - SCOPUS:85163827390
SN - 1748-0221
VL - 18
JO - Journal of Instrumentation
JF - Journal of Instrumentation
IS - 6
M1 - P06030
ER -