T1 - Fully 3D PET iterative reconstruction using distance-driven projectors and native scanner geometry
AU - Manjeshwar, Ravindra M.
AU - Ross, Steven G.
AU - Iatrou, Maria
AU - Deller, Timothy W.
AU - Stearns, Charles W.
PY - 2006
Y1 - 2006
N2 - Incorporating all data corrections into the system model optimizes image quality in statistical iterative PET image reconstruction. We have previously shown that including attenuation, randoms and scatter in the forward 3D iterative model results in faster convergence and improved image quality for ML-OSEM. This paper extends this work to allow the accurate modeling of crystal efficiency, detector deadtime, and the native block-based detector geometry. In order to model these effects, it is necessary to perform forward- and back-projections directly from image space to the projection geometry of the PET scanner, rather than to an idealized, equally spaced projection space. We have modified the distance-driven projectors to accurately model both the uneven spacing of the sinogram due to the ring curvature as well as the gaps resulting from the block structure of the scanner. This results in a reconstruction method, which can incorporate the crystal efficiency and block deadtime effects into the forward system model while maintaining the fast reconstruction times enabled by the distance driven projector design. Results on the GE Discovery STE™ scanner show improvements in image resolution consistent with removing the interpolative smoothing of the data into the equally spaced projection space.
AB - Incorporating all data corrections into the system model optimizes image quality in statistical iterative PET image reconstruction. We have previously shown that including attenuation, randoms and scatter in the forward 3D iterative model results in faster convergence and improved image quality for ML-OSEM. This paper extends this work to allow the accurate modeling of crystal efficiency, detector deadtime, and the native block-based detector geometry. In order to model these effects, it is necessary to perform forward- and back-projections directly from image space to the projection geometry of the PET scanner, rather than to an idealized, equally spaced projection space. We have modified the distance-driven projectors to accurately model both the uneven spacing of the sinogram due to the ring curvature as well as the gaps resulting from the block structure of the scanner. This results in a reconstruction method, which can incorporate the crystal efficiency and block deadtime effects into the forward system model while maintaining the fast reconstruction times enabled by the distance driven projector design. Results on the GE Discovery STE™ scanner show improvements in image resolution consistent with removing the interpolative smoothing of the data into the equally spaced projection space.
UR - http://www.scopus.com/inward/record.url?scp=38549098170&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2006.356461
DO - 10.1109/NSSMIC.2006.356461
M3 - Conference contribution
AN - SCOPUS:38549098170
SN - 1424405610
SN - 9781424405619
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 2804
EP - 2807
BT - 2006 IEEE Nuclear Science Symposium - Conference Record
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2006 IEEE Nuclear Science Symposium, Medical Imaging Conference and 15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors, Special Focus Workshops, NSS/MIC/RTSD
Y2 - 29 October 2006 through 4 November 2006
ER -