Abstract

Fenestrations are responsible for significant amount of energy consumption in the built environment and have significant impact on daylighting and occupant visual comfort. Balance between energy consumption and occupant well-being can be achieved using automated dynamic interior shading devices. However, empirical evidence on performance of dynamic shading devices is lacking. In this study, full- scale experimental testing of two types of roller shades using two different control strategies was performed across three different orientations during varying sky conditions. Each orientation utilized one baseline room with no shading device or lighting control, and a second identical room with integrated shading and lighting control. Two different glazing types were also used to assess the performance of roller shades when used along with different glazing types. An average of 52% energy savings was obtained for lighting and 26% for cooling while maintaining acceptable levels of glare more than 90% of the time across all orientations. The impact of factors including shading device, control strategy, orientation, sky conditions and other applicable environmental variables for energy savings, visual comfort, and daylighting are also discussed. The results of this work provide full-scale testing results and informative recommendations for the utilization of dynamic roller shades in real-world scenarios.

Original languageEnglish
Pages (from-to)17-28
Number of pages12
JournalSolar Energy
Volume186
DOIs
StatePublished - Jul 1 2019
Externally publishedYes

Funding

This project was funded by ASHRAE under the grant 1710-RP and supported by Iowa Energy Center and Pella Corporation . Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of ASHRAE, the Iowa Energy Center, or Pella Corporation. This project was funded by ASHRAE under the grant 1710-RP and supported by Iowa Energy Center and Pella Corporation. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of ASHRAE, the Iowa Energy Center, or Pella Corporation.

FundersFunder number
Iowa Energy Center and Pella Corporation
American Society of Heating, Refrigerating and Air-Conditioning Engineers1710-RP
Iowa Energy Center

    Keywords

    • Daylighting
    • Dynamic shading
    • Energy savings
    • Full-scale testing
    • Roller shades
    • Visual comfort