Abstract
A fully superconducting ECR ion source (ECRIS), SuSI (Superconducting Source for Ions) was constructed at the National Superconducting Cyclotron Laboratory at Michigan State University (NSCL/MSU) to replace the existing SC-ECRIS. This ECRIS operates at 18+14.5 GHz microwave frequencies. During the initial commissioning of the magnet, the axial field reached 3.6 T and 2.2 T at the injection and extraction, respectively. The radial field reached 2 T at the plasma chamber walls. These magnetic field values will be needed for a planned upgrade to 24-28 GHz in the second phase of commissioning. The first commissioning results of this new ECRIS are presented.
| Original language | English |
|---|---|
| Pages | 283-285 |
| Number of pages | 3 |
| State | Published - 2007 |
| Event | 18th International Conference on Cyclotrons and Their Applications 2007, CYCLOTRONS 2007 - Giardini Naxos, Italy Duration: Oct 1 2007 → Oct 5 2007 |
Conference
| Conference | 18th International Conference on Cyclotrons and Their Applications 2007, CYCLOTRONS 2007 |
|---|---|
| Country/Territory | Italy |
| City | Giardini Naxos |
| Period | 10/1/07 → 10/5/07 |