First commissioning results of the SuSI ECRIS

P. A. Závodszky, B. Arend, D. Cole, J. DeKamp, M. Doleans, G. Machicoane, F. Marti, P. Miller, J. Moskalik, W. Nurnberger, J. Ottarson, J. Vincent, X. Wu, A. Zeller

Research output: Contribution to conferencePaperpeer-review

1 Scopus citations

Abstract

A fully superconducting ECR ion source (ECRIS), SuSI (Superconducting Source for Ions) was constructed at the National Superconducting Cyclotron Laboratory at Michigan State University (NSCL/MSU) to replace the existing SC-ECRIS. This ECRIS operates at 18+14.5 GHz microwave frequencies. During the initial commissioning of the magnet, the axial field reached 3.6 T and 2.2 T at the injection and extraction, respectively. The radial field reached 2 T at the plasma chamber walls. These magnetic field values will be needed for a planned upgrade to 24-28 GHz in the second phase of commissioning. The first commissioning results of this new ECRIS are presented.

Original languageEnglish
Pages283-285
Number of pages3
StatePublished - 2007
Externally publishedYes
Event18th International Conference on Cyclotrons and Their Applications 2007, CYCLOTRONS 2007 - Giardini Naxos, Italy
Duration: Oct 1 2007Oct 5 2007

Conference

Conference18th International Conference on Cyclotrons and Their Applications 2007, CYCLOTRONS 2007
Country/TerritoryItaly
CityGiardini Naxos
Period10/1/0710/5/07

Fingerprint

Dive into the research topics of 'First commissioning results of the SuSI ECRIS'. Together they form a unique fingerprint.