Abstract
We overview the system design of the Pohang Light Source-II (PLS-II), and demonstrate that synchrotron radiation is the cause of a recent incident that damaged the vacuum components. To preclude further incidents, we designed a system that shuts off the beam if such damage is imminent. We used an ANSYS simulation to estimate the appropriate time allowed for this shut-off then. A Fast Interlock System is implemented to accomplish beam shut-off within this time. In bench test, this system shut down the beam within the acceptable time. The installation and the operation of the Fast Interlock System in PLS-II is planned.
| Original language | English |
|---|---|
| Pages (from-to) | 301-305 |
| Number of pages | 5 |
| Journal | Journal of the Korean Physical Society |
| Volume | 76 |
| Issue number | 4 |
| DOIs | |
| State | Published - Feb 1 2020 |
| Externally published | Yes |
Funding
This research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF-2019R1C1C1003412, NRF-2017R1D1A1B03033192).
Keywords
- Heat load
- Interlock
- Storage ring
- Synchrotron radiation
Fingerprint