Fabrication and evaluation of a copper flat micro heat pipe working under adverse-gravity orientation

H. T. Lim, S. H. Kim, H. D. Im, K. H. Oh, S. H. Jeong

Research output: Contribution to journalArticlepeer-review

58 Scopus citations

Abstract

The fabrication of a prototype flat micro heat pipe (FMHP) of a size appropriate for mobile electronics and its performance test results are reported. To ensure reliable operation under repeated thermal loads and to enhance the heat transport capacity, copper is selected as the packaging material considering its high thermal conductivity and good strength. The wick structure of the FMHP consists of fan-shaped microgrooves with a width and depth of about 100 and 200 νm, respectively. The fabrication of microgrooves was done using a laser micromachining technique and water was used as the working fluid. Fan-shaped microgrooves were found to induce a greater capillary pressure than triangular microgrooves of a similar size. Subsequent test results confirmed that despite its small size, 56 mm (L) × 8 mm (W) × 1.5 mm (H), the FMHP had a high heat transport capacity; the maximum heat transfer rate was 8 W under stable operation conditions and 13 W at the dryout point. In addition, the FMHP worked under adverse-gravity conditions with little change in cooling capacity, a key advantage for application in modern mobile electronics.

Original languageEnglish
Article number105013
JournalJournal of Micromechanics and Microengineering
Volume18
Issue number10
DOIs
StatePublished - Oct 1 2008
Externally publishedYes

Fingerprint

Dive into the research topics of 'Fabrication and evaluation of a copper flat micro heat pipe working under adverse-gravity orientation'. Together they form a unique fingerprint.

Cite this