TY - GEN
T1 - Experimental proof of record-short coincidence time resolution performance achieved in 3×3×3 mm3LYSO crystals
AU - Harmon, Eric S.
AU - Thompson, Michael O.
AU - Schmidtlein, C. Ross
AU - Turner, James N.
AU - Gola, Alberto
AU - Borghi, Giacomo
AU - Merzi, Stefano
AU - Moretti, Elena
AU - Krol, Andrzej
N1 - Publisher Copyright:
© COPYRIGHT SPIE. Downloading of the abstract is permitted for personal use only.
PY - 2023
Y1 - 2023
N2 - In this study, we re-evaluated the attainable coincidence time resolution (CTR) performance for 3×3×3 mm3 LYSO crystals coupled to matched 3×3 mm2 SiPMs. This work was motivated by potential increased sensitivity in brain positron emission tomography (PET) detector blocks that would be enabled with ultrashort CTR (<100 ps). The recent progress in silicon photomultiplier (SiPM) technology, high-frequency read-out circuits, and optimized data processing is expected to lead directly to improved performance. The 3×3×3 mm3 LYSO crystals, with all sides polished to optical quality, were optically coupled to SiPMs designed and fabricated by Fondazione Bruno Kessler (FBK). An improved high frequency read-out circuit was designed and fabricated. CTR was measured using a 22Na positron source (<10 μCi) sandwiched between two identical LYSO/SiPM/read-out circuit stacks. Our studies show that a CTR of less than 80 ps, which, to the best of our knowledge, is the shortest reported CTR for 3×3×3 mm3 LYSO crystals. The results demonstrate, for the first time, that CTR performance in 3×3×3 mm3 LYSO crystals coupled to a 3mm×3mm2 SiPMs is comparable to CTRs achieved for ultra-small LYSO crystals (2×2×3 mm3) coupled to large 4 × 4 mm2 SiPMs. These results prove that an array of 3×3×3 mm3 LYSO/SiPM can be used to build a next generation high performance detector block with very high packing fraction, enabling ultimately very high gamma ray detection efficiency and very high system sensitivity.
AB - In this study, we re-evaluated the attainable coincidence time resolution (CTR) performance for 3×3×3 mm3 LYSO crystals coupled to matched 3×3 mm2 SiPMs. This work was motivated by potential increased sensitivity in brain positron emission tomography (PET) detector blocks that would be enabled with ultrashort CTR (<100 ps). The recent progress in silicon photomultiplier (SiPM) technology, high-frequency read-out circuits, and optimized data processing is expected to lead directly to improved performance. The 3×3×3 mm3 LYSO crystals, with all sides polished to optical quality, were optically coupled to SiPMs designed and fabricated by Fondazione Bruno Kessler (FBK). An improved high frequency read-out circuit was designed and fabricated. CTR was measured using a 22Na positron source (<10 μCi) sandwiched between two identical LYSO/SiPM/read-out circuit stacks. Our studies show that a CTR of less than 80 ps, which, to the best of our knowledge, is the shortest reported CTR for 3×3×3 mm3 LYSO crystals. The results demonstrate, for the first time, that CTR performance in 3×3×3 mm3 LYSO crystals coupled to a 3mm×3mm2 SiPMs is comparable to CTRs achieved for ultra-small LYSO crystals (2×2×3 mm3) coupled to large 4 × 4 mm2 SiPMs. These results prove that an array of 3×3×3 mm3 LYSO/SiPM can be used to build a next generation high performance detector block with very high packing fraction, enabling ultimately very high gamma ray detection efficiency and very high system sensitivity.
KW - CTR
KW - Coincidence Timing Resolution
KW - Positron Emission Tomography
KW - SiPM
KW - brain PET
KW - effective sensitivity gain
KW - silicon photomultiplier
UR - https://www.scopus.com/pages/publications/85160923871
U2 - 10.1117/12.2656891
DO - 10.1117/12.2656891
M3 - Conference contribution
AN - SCOPUS:85160923871
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2023
A2 - Gimi, Barjor S.
A2 - Krol, Andrzej
PB - SPIE
T2 - Medical Imaging 2023: Biomedical Applications in Molecular, Structural, and Functional Imaging
Y2 - 19 February 2023 through 22 February 2023
ER -