TY - JOUR
T1 - Evaluation of Neutron Resonance Cross Section Data at GELINA
AU - Schillebeeckx, P.
AU - Becker, B.
AU - Capote, R.
AU - Emiliani, F.
AU - Guber, K.
AU - Heyse, J.
AU - Kauwenberghs, K.
AU - Kopecky, S.
AU - Lampoudis, C.
AU - Massimi, C.
AU - Mondelaers, W.
AU - Moxon, M.
AU - Noguere, G.
AU - Plompen, A. J.M.
AU - Pronyaev, V.
AU - Siegler, P.
AU - Sirakov, I.
AU - Trkov, A.
AU - Volev, K.
AU - Zerovnik, G.
N1 - Publisher Copyright:
© 2014 Elsevier Inc. All rights reserved
PY - 2014/5
Y1 - 2014/5
N2 - Over the last decade, the EC—JRC—IRMM, in collaboration with other institutes such as INRNE Sofia (BG), INFN Bologna (IT), ORNL (USA), CEA Cadarache (FR) and CEA Saclay (FR), has made an intense effort to improve the quality of neutron-induced cross section data in the resonance region. These improvements relate to both the infrastructure of the facility and the measurement setup, and the data reduction and analysis procedures. As a result total and reaction cross section data in the resonance region with uncertainties better than 0.5 % and 2 %, respectively, can be produced together with evaluated data files for both the resolved and unresolved resonance region. The methodology to produce full ENDF compatible files, including covariances, is illustrated by the production of resolved resonance parameter files for 241Am, Cd and W and an evaluation for 197Au in the unresolved resonance region.
AB - Over the last decade, the EC—JRC—IRMM, in collaboration with other institutes such as INRNE Sofia (BG), INFN Bologna (IT), ORNL (USA), CEA Cadarache (FR) and CEA Saclay (FR), has made an intense effort to improve the quality of neutron-induced cross section data in the resonance region. These improvements relate to both the infrastructure of the facility and the measurement setup, and the data reduction and analysis procedures. As a result total and reaction cross section data in the resonance region with uncertainties better than 0.5 % and 2 %, respectively, can be produced together with evaluated data files for both the resolved and unresolved resonance region. The methodology to produce full ENDF compatible files, including covariances, is illustrated by the production of resolved resonance parameter files for 241Am, Cd and W and an evaluation for 197Au in the unresolved resonance region.
UR - http://www.scopus.com/inward/record.url?scp=84991786064&partnerID=8YFLogxK
U2 - 10.1016/j.nds.2014.08.027
DO - 10.1016/j.nds.2014.08.027
M3 - Article
AN - SCOPUS:84991786064
SN - 0090-3752
VL - 119
SP - 94
EP - 97
JO - Nuclear Data Sheets
JF - Nuclear Data Sheets
ER -