Effects of helium implantation on hardness of pure iron and a reduced activation ferritic-martensitic steel

Hiroyasu Tanigawa, Shiro Jitsukawa, Akimichi Hishinuma, Masami Ando, Yutai Katoh, Akira Kohyama, Takeo Iwai

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

Helium was implanted into high purity Fe and F82H at room temperature up to 2000 appm to investigate helium effects on hardening. Ultra micro-indentation tests were performed on the specimens before and after helium implantation with loads that penetrate in 300 nm depth. After the indentation tests, the specimens were prepared with a focused ion beam (FIB) processing system for transmission electron microscopy (TEM) of the deformed regions. Results of the indentation tests indicated clearly that helium implantation caused hardening for both pure Fe and F82H. For pure Fe, it was also observed by TEM that the propagation of the plastic deformation zone formed during the indentation was limited to the helium-implanted layer, ranging from 600 to 800 nm from the incident surface.

Original languageEnglish
Pages (from-to)470-473
Number of pages4
JournalJournal of Nuclear Materials
Volume283-287
Issue numberPART I
DOIs
StatePublished - Dec 2000
Externally publishedYes

Fingerprint

Dive into the research topics of 'Effects of helium implantation on hardness of pure iron and a reduced activation ferritic-martensitic steel'. Together they form a unique fingerprint.