TY - GEN
T1 - Determination of plasma parameters in the PUPR mirror and cusp plasma machine via electrostatic probe methods
AU - Meyer, Ryan M.
AU - Rivera, Miguel A.
AU - Colmenares, Franklyn
AU - Leal, David
AU - Rivera, Ramon
AU - Gonzales, Angel
AU - Leal-Quiros, Edbertho
PY - 2006
Y1 - 2006
N2 - Electrostatic probes are constructed for the PUPR Mirror and Cusp Plasma Machine and preliminary measurements of the plasma parameters are obtained. The machine is cylindrical in shape with two copper coils wound around the machine to provide the necessary mirror or cusp field configuration. The plasma is heated using the electron cyclotron heating method at a frequency of 2.45 GHz. I-V characteristics are obtained using single, double, and emissive Langmuir probes in Argon plasma at approximately 1*10-4 Torr and with approximate field strength of ∼ 0.1T at the point cusp. The single and double Langmuir probes consist of 3.5 mm radius stainless steel disks. Characteristics are obtained for the single and double Langmuir probes using a source meter and programming a voltage sweep while recording the current from the digital readout. The emissive probe is constructed by using a tungsten filament and characteristics are obtained in a manner similar to that described for the single and double Langmuir probes. An emission current is superposed on top of the sweeping signal using a DC power source. An electron temperature of approximately 7.5eV is observed in the plasma at a density of ∼4.0*1014m-3 using the single Langmuir probe. In addition, with the distribution function obtained from the single probe, the plasma potential is observed to be approximately 25-30V. The measurement of 25-30V for the plasma potential is supported by measurements obtained from the emissive probe.
AB - Electrostatic probes are constructed for the PUPR Mirror and Cusp Plasma Machine and preliminary measurements of the plasma parameters are obtained. The machine is cylindrical in shape with two copper coils wound around the machine to provide the necessary mirror or cusp field configuration. The plasma is heated using the electron cyclotron heating method at a frequency of 2.45 GHz. I-V characteristics are obtained using single, double, and emissive Langmuir probes in Argon plasma at approximately 1*10-4 Torr and with approximate field strength of ∼ 0.1T at the point cusp. The single and double Langmuir probes consist of 3.5 mm radius stainless steel disks. Characteristics are obtained for the single and double Langmuir probes using a source meter and programming a voltage sweep while recording the current from the digital readout. The emissive probe is constructed by using a tungsten filament and characteristics are obtained in a manner similar to that described for the single and double Langmuir probes. An emission current is superposed on top of the sweeping signal using a DC power source. An electron temperature of approximately 7.5eV is observed in the plasma at a density of ∼4.0*1014m-3 using the single Langmuir probe. In addition, with the distribution function obtained from the single probe, the plasma potential is observed to be approximately 25-30V. The measurement of 25-30V for the plasma potential is supported by measurements obtained from the emissive probe.
UR - https://www.scopus.com/pages/publications/33847041078
U2 - 10.1063/1.2405996
DO - 10.1063/1.2405996
M3 - Conference contribution
AN - SCOPUS:33847041078
SN - 0735403759
SN - 9780735403758
T3 - AIP Conference Proceedings
SP - 493
EP - 496
BT - PLASMA AND FUSION SCIENCE
T2 - PLASMA AND FUSION SCIENCE: 16th IAEA Technical Meeting on Research using Small Fusion Devices; XI Latin American Workshop on Plasma Physics
Y2 - 30 November 2006 through 9 December 2006
ER -