N2 - In previous work we have demonstrated the use of neutrons to detect iron overload in the liver. We are developing a non-invasive technique to measure liver iron concentration in the human body through neutron inelastic scatter spectroscopy. The measurement is performed using an incident neutron beam that scatters inelastically with iron nuclei in the liver, causing characteristic gamma emission that is used to quantify the tissue iron content. Due to its high neutron flux, the Spallation Neutron Source (SNS) at ORNL presents anttractive option for initial development and optimization of the technique. In this manuscript we describe a simulation study to evaluate feasibility of the SNS beam for iron overload detection in the liver. An MCNPX simulation was developed to model the parameters of the SNS beam and scan a liver phantom with tissue iron content varying from 2 mg/g (mild iron overloaded) to 10 mg/g (severe iron overload). A torso phantom filled with water was placed around the liver and used to simulate scattering effects of the human torso. The emitted gamma spectrum was acquired with a simulated ring detector. Background subtraction was performed by substituting the liver with a water phantom. Background corrected spectra were analyzed to identify gamma lines corresponding to iron in the liver tissue. Statistically significant differences with p < 0.05 were identified for the 56Fe gamma line at 847 keY. Counts in the gamma line were found to be higher in the 10 mg/g sample by a factor of 4.72, differing by less than 6% from the expected value of 5. These results demonstrate the feasibility of the SNS beam to determine iron content in liver tissue.
AB - In previous work we have demonstrated the use of neutrons to detect iron overload in the liver. We are developing a non-invasive technique to measure liver iron concentration in the human body through neutron inelastic scatter spectroscopy. The measurement is performed using an incident neutron beam that scatters inelastically with iron nuclei in the liver, causing characteristic gamma emission that is used to quantify the tissue iron content. Due to its high neutron flux, the Spallation Neutron Source (SNS) at ORNL presents anttractive option for initial development and optimization of the technique. In this manuscript we describe a simulation study to evaluate feasibility of the SNS beam for iron overload detection in the liver. An MCNPX simulation was developed to model the parameters of the SNS beam and scan a liver phantom with tissue iron content varying from 2 mg/g (mild iron overloaded) to 10 mg/g (severe iron overload). A torso phantom filled with water was placed around the liver and used to simulate scattering effects of the human torso. The emitted gamma spectrum was acquired with a simulated ring detector. Background subtraction was performed by substituting the liver with a water phantom. Background corrected spectra were analyzed to identify gamma lines corresponding to iron in the liver tissue. Statistically significant differences with p < 0.05 were identified for the 56Fe gamma line at 847 keY. Counts in the gamma line were found to be higher in the 10 mg/g sample by a factor of 4.72, differing by less than 6% from the expected value of 5. These results demonstrate the feasibility of the SNS beam to determine iron content in liver tissue.
UR - http://www.scopus.com/inward/record.url?scp=67649194609&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2008.4774356
DO - 10.1109/NSSMIC.2008.4774356
M3 - Conference contribution
AN - SCOPUS:67649194609
SN - 9781424427154
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 4972
EP - 4975
BT - 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
Y2 - 19 October 2008 through 25 October 2008
ER -