Abstract
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-Type point contact detectors totaling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The DEMONSTRATOR uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at each detectors point contact. These low-mass cables and connectors must meet stringent radiopurity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the MAJORANA DEMONSTRATOR are being developed with the aim of increasing their overall reliability and connectivity. We will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.
Original language | English |
---|---|
Article number | 012129 |
Journal | Journal of Physics: Conference Series |
Volume | 1342 |
Issue number | 1 |
DOIs | |
State | Published - Jan 20 2020 |
Event | 15th International Conference on Topics in Astroparticle and Underground Physics, TAUP 2017 - Sudbury, Canada Duration: Jun 24 2017 → Jun 28 2017 |
Funding
This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, the Particle Astrophysics and Nuclear Physics Programs of the National Science Foundation, and the Sanford Underground Research Facility.