Abstract
Design criteria are established for the optimization of particle exhaust as a function of heat loads and the device parameters, and the results are applied to study the performance of a system of modular pump limiters. First, the characteristics and the basic parameters of a modular pump limiter are reviewed. The results are then applied to a modular system. The design considerations for this system are discussed in a model that gives the system exhaust efficiency in terms of the parameters of the device and the actively cooled leading edge. The model then is applied to the Tore Supra tokamak for estimating the conceptual design parameters of the pump limiter system.
Original language | English |
---|---|
Pages | 1402-1407 |
Number of pages | 6 |
State | Published - 1987 |