@inproceedings{d2618a7afbd8417bbcb6e31d8556086e,
title = "Critical speed measurements in the Tevatron cold compressors",
abstract = "The Fermilab Tevatron cryogenic system utilizes high-speed centrifugal cold compressors, manufactured by Ishikawajima-Harima Heavy Industries Co. Ltd. (IHI), for high energy operations. Nominal operating range for these compressors is 43,000 to 85,000 rpm. Past foil bearing failures prompted investigation to determine if critical speeds for operating compressors fall within operating range. Data acquisition hardware and software settings will be discussed for measuring liftoff, first critical and second critical speeds. Several tests provided comparisons between an optical displacement probe and accelerometer measurements. Vibration data and analysis of the 20 Tevatron ring cold compressors will be presented.",
keywords = "Cold compressors, Data acquisition system, Fermilab refrigeration system, Vibrations",
author = "B. DeGraff and R. Bossert and A. Martinez and Soyars, {W. M.}",
year = "2006",
month = apr,
day = "27",
doi = "10.1063/1.2202560",
language = "English",
isbn = "0735403171",
series = "AIP Conference Proceedings",
pages = "1392--1398",
booktitle = "ADVANCES IN CRYOGENIC ENGINEERING",
note = "ADVANCES IN CRYOGENIC ENGINEERING: Transactions of the Cryogenic Engineering Conference, CEC ; Conference date: 29-08-2005 Through 02-09-2005",
}