Critical speed measurements in the Tevatron cold compressors

B. DeGraff, R. Bossert, A. Martinez, W. M. Soyars

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

The Fermilab Tevatron cryogenic system utilizes high-speed centrifugal cold compressors, manufactured by Ishikawajima-Harima Heavy Industries Co. Ltd. (IHI), for high energy operations. Nominal operating range for these compressors is 43,000 to 85,000 rpm. Past foil bearing failures prompted investigation to determine if critical speeds for operating compressors fall within operating range. Data acquisition hardware and software settings will be discussed for measuring liftoff, first critical and second critical speeds. Several tests provided comparisons between an optical displacement probe and accelerometer measurements. Vibration data and analysis of the 20 Tevatron ring cold compressors will be presented.

Original languageEnglish
Title of host publicationADVANCES IN CRYOGENIC ENGINEERING
Subtitle of host publicationTransactions of the Cryogenic Engineering Conference, CEC, Volume 51B
Pages1392-1398
Number of pages7
DOIs
StatePublished - Apr 27 2006
Externally publishedYes
EventADVANCES IN CRYOGENIC ENGINEERING: Transactions of the Cryogenic Engineering Conference, CEC - Keystone, CO, United States
Duration: Aug 29 2005Sep 2 2005

Publication series

NameAIP Conference Proceedings
Volume823 II
ISSN (Print)0094-243X
ISSN (Electronic)1551-7616

Conference

ConferenceADVANCES IN CRYOGENIC ENGINEERING: Transactions of the Cryogenic Engineering Conference, CEC
Country/TerritoryUnited States
CityKeystone, CO
Period08/29/0509/2/05

Keywords

  • Cold compressors
  • Data acquisition system
  • Fermilab refrigeration system
  • Vibrations

Fingerprint

Dive into the research topics of 'Critical speed measurements in the Tevatron cold compressors'. Together they form a unique fingerprint.

Cite this