Cracking and performance of composite tubes and air port designs in a kraft recovery boiler

Joseph R. Kish, Douglas L. Singbeil, James R. Keiser, Angela Wensley, François Jetté

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Cracking of the 304L/SA-210 composite tubes has particularly affected a kraft recovery boiler belonging to one of Paprican's member companies. To evaluate the effectiveness of alternative solutions to this problem, test panels made with several types of composite tubes fabricated into two different port designs were installed in the boiler. These panels have been examined for cracking and corrosion of the cladding/overlay every six months since the time of their installation. The test panel with co-extruded modified A825/carbon steel composite tubes and port design designated "B" was the only one where no cracking or corrosion was found on any of the tubes after 30 months exposure.

Original languageEnglish
Title of host publication2004 International Chemical Recovery Conference
Pages555-574
Number of pages20
StatePublished - 2004
Event2004 International Chemical Recovery Conference - Charleston, SC, United States
Duration: Jun 6 2004Jun 10 2004

Publication series

Name2004 International Chemical Recovery Conference
Volume2

Conference

Conference2004 International Chemical Recovery Conference
Country/TerritoryUnited States
CityCharleston, SC
Period06/6/0406/10/04

Fingerprint

Dive into the research topics of 'Cracking and performance of composite tubes and air port designs in a kraft recovery boiler'. Together they form a unique fingerprint.