Continuous operation of 2.45-GHz microwave proton source for 306 hours with more than 50 mA DC beam

Shi Xiang Peng, Ai Lin Zhang, Hai Tao Ren, Tao Zhang, Yuan Xu, Jing Feng Zhang, Jian Hua Gong, Zhi Yu Guo, Jia Er Chen

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

This paper describes a long-term operation of the 2.45-GHz microwave proton source at Peking University. The DC proton beam of 50-55 mA with energy of 35 keV has been run for 306 hours continuously. Total beam availability, defined as 35-keV beam-on time divided by elapsed time, is higher than 99%. Water cooling machine failures cause all the downtime, and no plasma generator failure or high voltage breakdown is observed. The longest uninterrupted run time is 122 hours.

Original languageEnglish
Article number075203
JournalChinese Physics B
Volume24
Issue number7
DOIs
StatePublished - Jul 1 2015
Externally publishedYes

Funding

FundersFunder number
National Natural Science Foundation of China91126004

    Keywords

    • DC proton beam
    • ECR ion source
    • high voltage breakdown
    • plasma generator failure

    Fingerprint

    Dive into the research topics of 'Continuous operation of 2.45-GHz microwave proton source for 306 hours with more than 50 mA DC beam'. Together they form a unique fingerprint.