Abstract
This paper describes a long-term operation of the 2.45-GHz microwave proton source at Peking University. The DC proton beam of 50-55 mA with energy of 35 keV has been run for 306 hours continuously. Total beam availability, defined as 35-keV beam-on time divided by elapsed time, is higher than 99%. Water cooling machine failures cause all the downtime, and no plasma generator failure or high voltage breakdown is observed. The longest uninterrupted run time is 122 hours.
Original language | English |
---|---|
Article number | 075203 |
Journal | Chinese Physics B |
Volume | 24 |
Issue number | 7 |
DOIs | |
State | Published - Jul 1 2015 |
Externally published | Yes |
Keywords
- DC proton beam
- ECR ion source
- high voltage breakdown
- plasma generator failure