Abstract
Integral experiments that measure the transport of ∼ 14 MeV neutrons through a 0.30-m-diameter duct having a length-to-diameter ratio of 2.83 that is partially plugged with a 0.15 m diameter, 0.51 m long shield comprised of alternating layers of stainless steel type 304 and borated polyethylene have been carried out at the Oak Ridge National Laboratory. Measured and calculated neutron and gamma ray energy spectra are compared at several locations relative to the mouth of the duct. The measured spectra were obtained using an NE-213 liquid scintillator detector with pulse shape discrimination methods used to simultaneously resolve neutron and gamma ray events. The calculated spectra were obtained using a computer code network that incorporates two radiation transport methods: discrete ordinates (with P3 multigroup cross sections) and Monte Carlo (with continuous point cross sections). The two radiation transport methods are required to account for neutrons that singly scatter from the duct to the detectors. The calculated and measured neutron energy spectra above 850 keV agree within 5-50% depending on detector location and neutron energy. The calculated and measured gamma ray energy spectra above 750 keV are also in favorable agreement, ∼ 5-50%, depending on detector location and gamma ray energy.
Original language | English |
---|---|
Pages (from-to) | 403-412 |
Number of pages | 10 |
Journal | Journal of Fusion Energy |
Volume | 2 |
Issue number | 6 |
DOIs | |
State | Published - Dec 1982 |
Keywords
- analytic methods
- gamma-ray spectra
- integral experiments
- neutron spectra
- radiation streaming