Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

J. Balajthy, J. Brown, E. Brubaker, B. Cabrera-Palmer, J. Cates, B. Goldblum, M. Folsom, P. Hausladen, K. Keefe, J. Nattress, V. Negut, K. Nishimura, J. Steele, K. Ziock

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. We calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

Original languageEnglish
Article numberT06004
JournalJournal of Instrumentation
Volume19
Issue number6
DOIs
StatePublished - Jun 1 2024

Keywords

  • Inspection with neutrons
  • Neutron detectors (cold, thermal, fast neutrons)
  • Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs, CMOS imagers, etc)
  • Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators)

Fingerprint

Dive into the research topics of 'Characterization of a SiPM-based monolithic neutron scatter camera using dark counts'. Together they form a unique fingerprint.

Cite this