Abstract
The temperature and fluence dependence of cavity swelling and dislocation development in CVD SiC irradiated with fast neutrons at high temperatures (1050-1460 °C, up to 9.6 dpa) were evaluated using transmission electron microscopy. The cavity swelling was very limited below 1300 °C (<0.01% at 1300 °C, 9.3 dpa). Temperature and fluence dependent swelling became visible above ∼1400 °C. The maximum value of the cavity swelling was 0.25% at 1460 °C, 9.6 dpa, but this appeared to be below the peak swelling temperature. Frank loops were the dominant dislocation structure in this temperature regime, and the number density decreased and the size increased with increasing irradiation temperature. The loop microstructures depended less significantly on both the irradiation temperature and fluence below 1200 °C. A significant decrease in the number density and increase in the size were observed at 1300-1460 °C.
Original language | English |
---|---|
Pages (from-to) | 222-226 |
Number of pages | 5 |
Journal | Journal of Nuclear Materials |
Volume | 386-388 |
Issue number | C |
DOIs | |
State | Published - Apr 30 2009 |
Funding
This research was sponsored by the Office of Fusion Energy Sciences, US Department of Energy under contract DE-AC05-00OR22725 with UT-Battelle, LLC.
Funders | Funder number |
---|---|
US Department of Energy | DE-AC05-00OR22725 |
Fusion Energy Sciences |