TY - GEN
T1 - Breast cancer diagnosis using neutron stimulated emission computed tomography
T2 - Medical Imaging 2006: Physics of Medical Imaging
AU - Floyd, Carey E.
AU - Bender, Janelle E.
AU - Harrawood, Brian
AU - Sharma, Amy C.
AU - Kapadia, Anuj
AU - Tourassi, Georgia D.
AU - Lo, Joseph Y.
AU - Howell, Calvin
PY - 2006
Y1 - 2006
N2 - Neutron Stimulated Emission Computed Tomography (NSECT) was evaluated as a potential technique for breast cancer diagnosis. NSECT can form a 3D tomographic image with an elemental (isotopic) spectrum provided at each reconstructed voxel. The target is illuminated (in vivo) by a neutron beam that scatters in-elastically producing characteristic gamma emission that is acquired tomographically with a spectrograph. Images are reconstructed of each element in the acquired spectrum. NSECT imaging was simulated for benign and malignant breast masses. A range of the number of incident neutrons was simulated from 19 million to 500k neutrons. Simulation included all known primary and secondary physical interactions in both the breast as well as in the spectrometer. Characteristic energy spectra were acquired by simulation and were analyzed for statistically significant differences between benign and malignant breasts. For 1 million incident neutrons, there were 61 differences in the spectra that were statistically significant (p < 0,05), Of these, 23 matched known characteristic emission from 6 elements that have been found in the breast (Br, Cs, K, Mn, Rb, Zn). The dose to two breasts was less than 3% of the dose of a 4 view screening mammogram, Increasing the dose to 52% of the mammogram (19 million neutrons) provided 89 significant spectral differences that matched 30 known emissions from 7 elements that have been found in the breast (Br, Co, Cs, K, Mn, Rb, Zn). Decreasing the dose to 1.4% (500K neutrons) eliminated all statistically significant matches to known elements. This study suggests that NSECT may be a viable technique for detecting human breast cancer in vivo at a reduced dose compared to 4 view screening mammography.
AB - Neutron Stimulated Emission Computed Tomography (NSECT) was evaluated as a potential technique for breast cancer diagnosis. NSECT can form a 3D tomographic image with an elemental (isotopic) spectrum provided at each reconstructed voxel. The target is illuminated (in vivo) by a neutron beam that scatters in-elastically producing characteristic gamma emission that is acquired tomographically with a spectrograph. Images are reconstructed of each element in the acquired spectrum. NSECT imaging was simulated for benign and malignant breast masses. A range of the number of incident neutrons was simulated from 19 million to 500k neutrons. Simulation included all known primary and secondary physical interactions in both the breast as well as in the spectrometer. Characteristic energy spectra were acquired by simulation and were analyzed for statistically significant differences between benign and malignant breasts. For 1 million incident neutrons, there were 61 differences in the spectra that were statistically significant (p < 0,05), Of these, 23 matched known characteristic emission from 6 elements that have been found in the breast (Br, Cs, K, Mn, Rb, Zn). The dose to two breasts was less than 3% of the dose of a 4 view screening mammogram, Increasing the dose to 52% of the mammogram (19 million neutrons) provided 89 significant spectral differences that matched 30 known emissions from 7 elements that have been found in the breast (Br, Co, Cs, K, Mn, Rb, Zn). Decreasing the dose to 1.4% (500K neutrons) eliminated all statistically significant matches to known elements. This study suggests that NSECT may be a viable technique for detecting human breast cancer in vivo at a reduced dose compared to 4 view screening mammography.
KW - Neutrons in Imaging
KW - Novel Methods (OT)
KW - Simulation (SIM)
UR - http://www.scopus.com/inward/record.url?scp=33745368905&partnerID=8YFLogxK
U2 - 10.1117/12.656045
DO - 10.1117/12.656045
M3 - Conference contribution
AN - SCOPUS:33745368905
SN - 0819461857
SN - 9780819461858
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2006
Y2 - 12 February 2006 through 16 February 2006
ER -