Assessment of the Subchannel Code CTF for Single- and Two-Phase Flows

Xingang Zhao, Aaron J. Wysocki, Koroush Shirvan, Robert K. Salko

Research output: Contribution to journalArticlepeer-review

10 Scopus citations

Abstract

As part of the Consortium for Advanced Simulation of Light Water Reactors, the subchannel code CTF is being used for single-phase and two-phase flow analysis under light water reactor operating conditions. Accurate determination of flow distribution, pressure drop, and void content is crucial for predicting margins to thermal crisis and ensuring more efficient plant performance. In preparation for the intended applications, CTF has been validated against data from experimental facilities comprising the General Electric (GE) 3 × 3 bundle, the boiling water reactor full-size fine-mesh bundle tests (BFBTs), the Risø tube, and the pressurized water reactor subchannel and bundle tests (PSBTs). Meanwhile, the licensed, well-recognized subchannel code VIPRE-01 was used to generate a baseline set of simulations for the targeted tests and solution parameters were compared to the CTF results. The flow split verification problem and single-phase GE 3 × 3 results are essentially in perfect agreement between the two codes. For the two-phase GE 3 × 3 cases, flow and quality discrepancies arise in the annular-mist flow regime, yet significant improvement is observed in CTF when void drift and two-phase turbulent mixing enhancement are considered. The BFBT pressure drop benchmark shows close agreement between predicted and measured results in general, although considerable overprediction by CTF is observed at relatively high void locations of the facility. This overestimation tendency is confirmed by the Risø cases. While overall statistics are satisfactory, both BFBT and PSBT bubbly-to-churn flow void contents are markedly overpredicted by CTF. The issues with two-phase closures such as turbulent mixing, interfacial and wall friction, and subcooled boiling heat transfer need to be addressed. Preliminary sensitivity studies are presented herein, but more advanced models and code stability analysis require further investigation.

Original languageEnglish
Pages (from-to)338-351
Number of pages14
JournalNuclear Technology
Volume205
Issue number1-2
DOIs
StatePublished - Jan 2 2019

Funding

This research was supported by CASL (www.casl.gov), an Energy Innovation Hub (http://www.energy.gov/hubs) for modeling and simulation of nuclear reactors under DOE contract DE-AC05-00OR22725.

FundersFunder number
Energy Innovation Hub
U.S. Department of EnergyDE-AC05-00OR22725
Center for Applied Strategic Learning

    Keywords

    • CTF
    • flow mixing
    • pressure drop
    • subchannel analysis
    • void fraction

    Fingerprint

    Dive into the research topics of 'Assessment of the Subchannel Code CTF for Single- and Two-Phase Flows'. Together they form a unique fingerprint.

    Cite this