Abstract
During reprocessing operations, accurately determining the elemental concentrations of uranium and plutonium is critical for nuclear security. Reprocessing facilities processes hundreds of tons of nuclear material annually, requiring accurate measurements to ensure effective nuclear material control and accountability. Hybrid K-edge densitometry (HKED) system combines K-edge absorption densitometry with x-ray fluorescence to measure actinide elemental concentrations with a low uncertainty. This system uses high-purity germanium gamma-ray detectors and advanced signal processing equipment to detect x-ray accurately. This document provides guidance on how to achieve effective performance from an HKED system for measuring uranium and plutonium concentrations in reprocessing facilities. It includes best practices for the setup and operation of an HKED system, while highlighting factors influencing uncertainties.
Original language | English |
---|---|
Place of Publication | United States |
DOIs | |
State | Published - 2024 |
Keywords
- 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS